STANDARDS
PREMIERFLEX 4000 complies with the requirements and
tolerance levels of :
1.The American Societty For Testing & Material ASTM
D-6164 Type II.
2.UEAtc (European Union of Technical Agreement).
3.MOAT 27-1983 and MOAT 30-1984.
4.CGSB (Canadian General Standards Board) 37-GP56M-July 1980.
INSTALLATION
TOOLS REQUIRED
Gas torch,
Knife, Trowel, Measuring tape, Marking string, Gloves.
APPLICATION
PREMIERFLEX 4000 is installed by
torch welding method, loose-laid or fully bonded to substrate. When
loose-laid, only laps are bonded together. Peripheries and
protrusions are sealed according to specifications.
COVERAGE
RATE
|
For
flat areas
|
1.13
M2/M2 per layer |
|
For
30 cm. girth flashing
|
0.35
M2/Mt/ length
|
|
Average
wastage
|
3
- 5%
|
TORCHING
GUIDELINES
The
underside of the membrane should be torched just enough to
superficially melt the bitumen. Excessive heating may damage the
reinforcement. Overlaps should be re-heated from the top and
resealed with a trowel to ensure seam integrity.
For
details of installation methods and flashing requirements, consult
the relevant BITUMAT Design and Installation Manual.