STANDARDS
POLYBOND complies with the requirements of the tolerance
levels of the following standards:
NF P 84314 Type 40 VV (France)
DIN 52131 V60 S4 (West Germany).
INSTALLATION
TOOLS REQUIRED
Gas torch,
Knife, Trowel, Measuring tape, Marking string, Gloves.
APPLICATION
POLYBOND is installed by torch welding
method, loose-laid or fully bonded to substrate. When loose-laid,
only laps are bonded together. Peripheries and protrusions are
sealed according to specifications.
COVERAGE
RATE
|
For
flat areas
|
1.13
M2/M2 per layer |
|
For
30 cm. girth flashing
|
0.35
M2/Mt/ length
|
|
Average
wastage
|
3
- 5%
|
TORCHING
GUIDELINES
The
underside of the membrane should be torched just enough to
superficially melt the bitumen. Excessive heating may damage the
reinforcement. Overlaps should be reheated from the top and resealed
with a trowel to ensure seam integrity.For details of installation
methods and flashing requirements, consult the relevant BITUMAT
Design and Installation Manual.