The
fiber board or backer rod can be adhered to the joint wall with this
application of JOINTSEAL-C. The backer rod or other filler material
is desirable to equalize the compression of the sealant induced by
joint movement and to reduce the thickness of the sealant. On
traffic bearing surfaces, the sealant should be slightly sanded to
prevent sticking.
Sealant Thickness
Maximum sealant thickness should be 10mm. It is
recommended that the application takes place in two stages of 5 mm
each, allowing 4-8 hours of curing time between each application in
order to expedite curing and minimize shrinkage cracking.
CLEANING
Tools : Clean with kerosene
Hands : Use a hand cleaner or kerosene followed by soap and water.
PACKING
20-kg pails and 200-kg drums.
HEALTH
& SAFETY
Contains petroleum distillate; flammable;
keep away from open fire, sparks or other ignition sources. Wear
protective clothing, gloves and goggles.
1 . Fire - Flammable when wet, flash point 40 °C.
2. Skin - Avoid repeated or prolonged contact; if contact occurs
remove with hand cleaner that removes oil or grease; then clean with
soap and water.
3. Eyes- Contact could cause irritation. If contact occurs flush
with clean water.
4. Inhalation - Can cause dizziness. Remove to fresh air and if
breathing difficulty persist administer oxygen.